Elimstat Overhead Blowers can be placed “overhead” by blowing ionizing air down on the product at a workstation; or “behind” a conveyor by shooting ionizing air horizontally across the product.

• Built-in emitter point cleaners and hand-operated electrode cleaners for each fan.

Prices

ProductQty 1Qty 2+
Elimstat Overhead Blower$1,182.00$1,097.14

Specs

DimensionSpecification
Discharge Time1.0 sec @ 1’ (0.3 m) center blower position; fan high(1000-100V) (Tested in accordance with ANSI /ESD STM3.1-2015)
Coverage AreaOverhead Applications: 2’W x 3’L (0.6m x 0.9m) ; Horizontal Applications: 3’ W x 5’ L (0.9m x 1.5m)
Weight13 lb (5.9 kg)
Dimensions35.5”L x 4.0”H x 6.25”D (900 x 100 x 160 mm)
Audible Noise59-69 dBA (max) measured at two feet from the blower.
MaintenanceBuilt-in emitter point cleaners and hand-operated electrode cleaners for each fan.
Operating EnvironmentOperates between 50-90 degrees Fahrenheit.
Input VoltageOperates at 120 VAC, 50/60Hz for use in North America

Maintenance

Operation. The Elimstat© Overhead Blower removes the build-up of potentially damaging static charges on non-conductive materials. Controlled with variable speeds a recessed speed control discourages tampering with the speed.
Maintenance. Built-In Emitter Point Cleaners and hand operated electrode cleaners make it a low maintenance unit.
Hand clean the electrode grill of each fan to remove dust and particles from it by turning the controls as shown below.

Testing. Everytime the unit is turned on it conducts a self-test to confirm balance and output compliance.
Ion Emission. The unit utilizes inherently balanced A/C Corona Technology.

AC Corona Ionization

AC Corona Ionization. When an AC ionizer is used high voltage is applied to a single emitter point that cycles between negative and positive at line frequency (50/60 Hz). Since the cycles are so fast, there is a high level of recombination of ions.

When should I use an AC Air Ionizer?

AC corona ionization is most appropriately used in industrial applications where the ionizer can be placed close to the charged objects and cleanliness is not required.

How does ESD Air Ionization Work?

When AC (alternating current) or DC (direct current) is applied to a sharp emitter point it creates an electric field or “corona” around the emitter. This high voltage corona of ions then interacts with electrons in the nearby gas molecules “cleaning” the air of unwanted charged air molecules.

ESD Air ionizers are used to remove static electric charges from the surfaces of ungrounded objects. (Keep in mind, you can use anti static mats to ground table tops and standing surfaces.) However, if you need to make sure static is not building up on your workstations consider using ESD air ionization.

Reviews

There are no reviews yet.

Be the first to review “Elimstat Overhead ESD Air Ionizing Fan”

You may also like…